第31卷 第13期 2015正 农业工程学报 Transactions of the Chinese Society of Agricultural Engineering vol-31 NO.13 7月 Jul_2015 28l 冷库冰水混合间接换热器的传热与流动特性 周福君,潘小莉,王文明 (东北农业大学工程学院,哈尔滨150030) 摘要:北方地区冬季寒冷漫长,夏季炎热,冬季储冰夏季利用有利于节能减排。利用冰水混合间接换热系统进行冷量 交换,不仅节能环保而且空气质量明显提高。采用有限体积法商业软件FLUENT,应用SIMPLE算法对翅片管式换热器 平直翅片的换热与流动特性进行数值研究,计算结果与试验结果对比分析。结果表明:数值模拟与试验偏差不超过15%; 迎面风速均匀分布情况下,随着迎面风速的增加,换热系数和压降分别增加了133%和428%;平均场协同角随迎面风速 的增加而增大,速度场和温度场的协同程度变差,对换热不利;在相同的空气体积流量下,迎面风速沿冰水流动方向呈 逐渐降低的分布方式对换热有利。 关键词:传热;冰;冷藏;自然冷资源;翅片管换热器;平直翅片;数值模拟;场协同 doi:10.11975 ̄.issn.1002—6819.2015.13.039 中图分类号:TK172 文献标志码:A 文章编号:1002—6819(2015)一13—0281—05 周福君,潘小莉,王文明.冷库冰水混合间接换热器的传热与流动特 陛[J].农业工程学报,2015,31(13):281--285. doi:10.11975/j.issn.1002—6819.2015.13.039 http://w tcsae.org Zhou Fujtin,Pan Xiaoli,Wang Wenming.Heat transfer and lfOW performance of indirect heat exchanger by mixed ice water based on natural cold resource[J].Transactions of the Chinese Society of Agricultural Engineering(Transactions of he tCSAE), 2015,31(131:28l一285.(in Chinese with English abstract)doi: 10.11975 issn.1002—6819.2015.13.039 http://www.tcsae.org 0引 言 中国北方地区冬季寒冷漫长,夏季炎热,冬季储冰 不同操作参数对所求问题的影响,与试验结果进行对比, 验证了本模型和方法的正确性。同时,为进一步优化设 计翅片管式换热器提供参考依据,大幅降低试验成本。 夏季利用可以有效节约能源。利用自然资源冷量进行生 鲜农产品保鲜、贮藏有利于节能环保。温度和湿度是果 蔬保鲜、房间空调、冷库及食品保鲜等技术的重要参数, 如何控制温、湿度是保证鲜活农产品,尤其是蔬菜和瓜 果产品质量的关键所在【1]。目前大型制冷系统采用电能驱 动,一方面由于使用了制冷剂造成环境污染,另一方面 消耗大量能源[2~1。在能源危机和环境污染日益严峻的情 况下,利用自然冷资源储藏蔬菜水果即节约资源又保护 环境,是一种绿色能源。换热器是热量传递的关键设备, 试验采用自行设计开发的平直翅片管式换热器 ,冰释放 冷量后转化为水,代替制冷剂以间接换热、内循环制冷 方式,提高空气质量,加快降温速度,储冰室与保鲜库 分开,实现温度自动控制和多点同时降温。温度接近0 的冰水在换热器内定速流动,环境热空气经风机吹向翅 1 试验装置和方法 1.1 试验装置 片管式换热器。翅片管式换热器是进行制冷剂一空气间热 交换,而空气侧热阻在整个热阻中起主导作用[5】,因此为 了提高换热性能,前人常常采用增大翅片的换热面积、 波纹翅片表面、百叶窗翅片表面、翅片开缝等具有增大 扰流的表面[6-Sl。在增强换热性能方面,利用CFD[ ]技 术进行翅片管式换热器的研究,可以形象直观的观测到 收稿日期:2015.01.28 修订日期:2015-06 17 试验用密闭保鲜库的大小为2 m×2 m×2 rfl。试验 装置系统如图1所示,它主要包括风机、机架、翅片管 式换热器、水泵及一些辅助设备,如过滤网、电磁阀、 传感器、管线等。试验中需要测量的物理量有空气入口、 出口的干、湿球温度和流量、冰水的入口、出口温度及 其流量、空气的相对湿度、迎面风速等。利用传感器将 采集的信号经数据采集卡传入计算机,通过虚拟仪器进 行控制。建立了一套完整的监测系统,对试验数据实时 监测和存储。仪器仪表在测试前都进行了校正,能满足 试验精度的要求。迎面风速的测定取风机出口界面5个 点的速度,取其平均值。试验中风机的风量和水泵的流 量通过变频器来调节。 冰水池中直径大小为10 cm左右的冰球与水混合, 理论温度为0,但随着冰球不断融化水温升高,试验中采 用溢流口使水面刚好覆盖冰球,并搅动水池使冰水温度 维持在0.5。利用水泵将一定流速的低温冷水打入翅片管 式换热器中,冰水在换热盘管中自上而下流动,环境热 空气横掠翅片管,冰水通过紫铜管内壁吸收流经管外表 面和翅片表面的显热而升温,入水口、出水口温度差在 2~3℃之间。经冷却后的空气由风机吹入储藏间,与部 分室外新鲜空气混合后再次作为来流空气与换热器进行 基金项目:国家科技支撑计划课题(2014BAD06B04.04) 作者简介:周福君,男,博士,教授,博士生导师,主要从事农业机械化工 程、农业机械设计、机电一体化研究。哈尔滨150030。Email:fjzhou@163.com 东北农业大学工程学院, 282 农业工程学报(http://www.tcsae.org) 2015年 换热。翅片管式换热器的管直径为10 i/lnl紫铜圆管,管 1.3控制方程 本文采用三维流动,稳态求解器,假设空气为不可 束按正三角形叉排排列,每排16根共四排。 压缩、湍流流动选用标准的 漠型。空气物性参数为常 数。控制方程如下[14-15]: 1)连续性方程: + + :0 x ay 8z (1) 式中:U,v,W为速度矢量在 , ,z方向上的分量 2)动量方程: n罢+V考++w , )l: ( 【 + +雾+ ] 一篆c2 l冰泵2.滤网3.阀门4.流量计5.电磁阀6.翅片管式换热器7.风机 8.壳体9.冰水池 1.Pump 2.Filter 3.Valve 4.Flow metre 5.Magnetic valve 6.Tube-and-fin heat exchanger 7.Fan 8.Shell 9.Water tank 图l试验装置 Fig.1 Experimental set-up 1.2物理模型 本文研究的是常见整体式平直翅片管,数值模拟的 参数为:管外径10 mill,管壁厚0-3 otni,纵向问距 12.5 mm,横向间距21.65 mm,翅片间距4 arn1,翅片厚 度0.2 mnl,翅片横向长度80.45 i/lnl。考虑翅片管式换热 器铜管与铝翅片的周期性,取最小重复单元作为计算区 域,如图2所示。空气以1.5~4 m/s的流速横掠翅片管, 空气来流温度取12℃,为试验中系统稳定后的温度。假 设翅片导热系数为无限大,即翅片效率为1,这对结果的 定性结论没有影响,给数值模拟带来很大的便利,翅片 表面设定为等温,与管内冰水温度相等取0,冰水流量 0.9 m /h。沿空气流动方向上为了防止流出边界回流,入 口延长5倍的管外径,出口延长7倍的管外径。采用 ANSYS的网格生成软件ICEM进行网格结构划分,六面 体网格质量0.837,网格质量好,易收敛。在近壁区变量 变化梯度大,采用网格加密处理,进行网格无关性检测, 最终选定网格的总结点数为825528。 ,,,、、厂、 \ \ { 厂、\|厂、 u\/ \/ 对称边界 \ ymmetry boundar a.俯视图 a.Topview 、 f J J 囝 对 际边界 creme1 both ldarv b.侧视图 b.Sideview 图2计算区域 Fig 2 Computational domain U + ++w w j l( + +窘+ 广 窘)_筹c3 0wn +y +w ]=∥f【 + + J窘]一 篆c4 式中:P为微元体上的压力,Pa;P为流体密度,kg/m ; 为动力黏度,N・s/m2。 3)能量方程: “ a 呶 o .a Ov DTz p kc f \l ‘ aO ax ‘+ + 0 jz‘1] , -、 式中: 为比热容,J/(kg・℃);T为温度,℃;k为流体 的传热系数,W/(m2-K1。 1.4边界条件及数值算法 模型中上下翅片的中心面定义为周期性边界条件, 空气进口速度、温度恒定且为均匀分布,空气与冰水均 采用速度入口、压力出口边界条件。延长区域的参数变 化极小,计算时选粗网格。翅片根部与铜管的接触热阻 忽略不计。翅片及管外壁与空气间对流换热采用流固耦 合方法,管壁、翅片表面为无渗透、无滑移。压力与速 度耦合采用SIMPLE算法,对流项离散采用二阶迎风格 式。其余边界条件为周期性、对称性边界条件[16-17]。 2数值模拟与试验结果分析 考虑到冰水一空气“二循环”系统必须相互匹配,需 要对每一系统的关键功能参数进行试验研究。随着冰水 流量的增加,冰水在换热管中流速增加,冰水与内壁问 的对流换热强度增大,流速增加使冰水在管内停留时间 短,翅片管外表面温度低,与环境热空气的换热量增加 而使出风口温度降低。当冰水流量达到0.9 m /h时,继续 增大流量,出风口温度基本不变,取此流量为最佳冰水 流量值。 2.1 迎面风速对流动和换热的影响 本文对来流空气流速分别为1.5、2、2.5、3、3.5、4 m/s 工况下进行数值计算,得到空气侧对流换热系数平均值 和压力降随迎面风速的变化规律,如图3所示。 如图3可知,换热系数的数值模拟结果与试验结果 吻合良好,误差在8%以内。迎面风速增加使换热系数增 加,增加趋势减缓。分析原因为提高迎面风速使通过的 空气流量增加,同时增强翅片表面间的空气扰动,强化 第13期 周福君等:冷库冰水混合间接换热器的传热与流动特性 283 对流换热使换热系数增大,但这是以增加压力损失为代 价的。当风速过大,环境热空气与冷翅片管的接触换热 时间减少,换热不充分即被吹出换热器。在模型中忽略 了辐射换热、重力及浮力带来空气扰动的影响,试验中 被冷却的空气和环境空气混合再次作为入口空气进行换 热,温度低于模型中恒定的入口温度,这些因素使空气 侧换热系数的试验值大于计算值。从经济性方面考虑, 选择较小的压力降的同时,又能保证翅管的换热性能, 本试验最佳风速值在2.5~3 m/s之间。 迎面风速 Head wind velocity/(m・s’ 1 a.侧换热系数 a.Air-side surface heat transfer coefifcient 迎面风速 Head wind velocity/(m・s 1 b.压降 b.Pressure drop 图3不同迎面风速对空气侧换热系数和压降的影响 Fig.3 Influence of different head wind velocities on air-side surface heat transfer coefficient and pressure drop 如图3可知,换热系数的数值模拟结果与试验结果 吻合良好,相对误差在8%以内。迎面风速增加使换热系 数增加,增加趋势减缓。分析原因为提高迎面风速使通 过的空气流量增加,同时增强翅片表面间的空气扰动, 强化对流换热使换热系数增大,但这是以增加压力损失 为代价的。当风速过大,环境热空气与冷翅片管的接触 换热时间减少,换热不充分即被吹出换热器。在模型中 忽略了辐射换热、重力及浮力带来空气扰动的影响,试 验中被冷却的空气和环境空气混合再次作为入口空气进 行换热,温度低于模型中恒定的入口温度,这些因素使 空气侧换热系数的试验值大于计算值。从经济性方面考 虑,选择较小的压力降的同时,又能保证翅管的换热性 能,本试验最佳风速值在2.5~3 rn/s之间。 随着迎面风速的增大,压降递增趋势显著,模拟值 与试验值的最大偏差不超过12%。在数值模拟中,设定 空气的入口流速方向与管束垂直且流速呈均匀分布,在 实际中是无法实现的。压差值与入口空气的流动状态密 切相关,试验中空气的入口方向不均匀及空气产生波动,Bd/d2々o§∞8jd 使得压力差值比模拟值偏大。轴流风机出风的特点使得 个别点空气波动较大,会造成误差偏大的情况。 2.2场协同分析 本研究采用数值模拟方法,以场协同理论[18-20】为指 导,对三维湍流流动中的流场和温度场进行分析。场协 同理论指出,对流换热的特性不仅取决于流体与固体壁 面之间的温差、流动速度和流体的热物理性质,还取决 于流体速度矢量与热流矢量间的夹角。在速度和温度条 件不变的情况下,其协同程度好则换热效果好。 ・V = ・1wl・cosfl (6) 式中: 为速度矢量,rn/s;V 为温度梯度,K/ml助 场协同角。 由式(6)可知,在一定的速度梯度和温度梯度下, 减小场协同角度有利于换热。 研究不同迎面风速1.5~6 m/s工况下,利用FLUENT 自带的Custom Field Functions功能,得到不同迎面风速 下的平均场协同角。迎面风速与平均场协同角的变化规 律如图4所示。 嫒 匿 盎 露 迎面风速 Head wind veloeity/(m’s’’、 图4不同迎面风速对平均场协同角的影响 Fig.4 Influence of different head wind velocities on average field synergyangles 如图4可知,在迎面风速均匀分布的情况下,随着 迎面风速的增大平均场协同角随之增大,迎面风速在 2.5~3 rn/s范围内,增加趋势变缓,风速达到3.5 m/s后, 平均场协同角曲线趋于水平。分析为随迎面风速的增加 使平均场协同角随之增加的速率变缓,速度场与温度场 的协同程度变差,换热系数增加趋于平缓。这进一步证 明了图3中的换热系数随迎面风速增长而趋势渐缓。当 流速增大到某一程度时,这种强化的流体流动并不能强 化换热,而且还有可能削弱换热。 2.3迎面风速方向对流动和换热的影响 来流速度分布对换热器的性能影响明显,在风机和 换热器之间加装导流板,改变气流进入的角度,固定迎 面风速为3 rn/s、冰水流量0.9 m3/h时,进行模拟和试验 研究。 数值模拟不同来流入角对制冷量的影响如图5所示。 气流速度与水平面的夹角为0,向下偏时角度为负,向上 偏转时为正。来流入角为0时,空气水平吹入换热盘管, 气流在盘管间分布均匀;当 位于一15。~15。之间时,气 284 农业工程学报(http://www.tcsae.org) 2015年 流分布基本均匀;当 向上或向下偏转过多时,容易发 生气流短路现象,局部区域甚至没有气流分布。分析原 因为当来流入角小于-15。或大于15。,会引起气流分布不 均匀,有些区域没有气流分布或形成涡流,致使速度矢 量和温度矢量间的夹角增大,场协同程度变差而使换热 效果不佳。当来流入角在-15。~l5。之间时,气流流场分 布较均匀,换热效果好。 一+数值 ̄lNu试验佩Exp鲥menfmerieail l svalumuue |ation ≥ 4 0一 扫 篓’萝/ ∞ 毒 , | ‘、 \ . . . 2 0 -50-40.30—20.10 0 10 20 30 40 50 入口来流角 Air inlet direetiorg(。) 图5不同来流入角对换热量的影响 Fig.5 Influence of different velocity angles of inlet air on heat transfer rate 在数值模拟中,假定翅片管外表面温度恒定不变,故 换热量曲线呈对称分布。而试验中,冰水沿翅片换热器自 上而下流动,换热器入水口与出水口温度差范围在1.6~ 2 ̄C之间。翅片管温度沿着换热器高度方向呈线性减少分 布。随着偏转角度的增加,制冷量先增加后减少,最佳导 流板偏转角度为向上偏转30。,较不偏转时制冷量增加了 19%,可见迎面风速分布方式对换热影响显著。分析为导 流板向上偏转时,更多的风量集中在换热器上部低温区 域,使上部分换热强度增强,下部区域风速小,上、下区 域温度差为0-3~0.7℃。试验证明,翅片管外侧风量沿冰 水流动方向呈逐渐降低的分布方式,对换热更有利。 3结论 在本试验研究中,CFD模拟与试验结果误差不超过 15%,两者吻合度较好,验证了模型建立的正确性。 试验研究表明,迎面风速对换热器的性能影响较大, 迎面风速分别取1.5~4 m/s 6个不同值,随着迎面风速的 增加,换热系数和压降分别增加了133%和428%,但换 热系数随风速的增加趋势变缓。迎面风速在1.5~3.5 m/s 范围内时,平均场协同角度增加了12%,协同程度变差, 当风速达到3.5 m/s后,协同角度几乎不随风速变化。最 佳迎面风速范围介于2.5~3 m/s之间。 来流入角对换热器内的气流分布有重要影响,过高 或过低的来流入角会产生涡流及气流分布不均匀,影响 传热性能。采用等壁温的数值模拟方法与试验偏差大。 来流入角从 5。增加到30。时,制冷量增加了70.6%,取 来流入角为30。换热器的传热性能较好。 [参考文献] [1] 周福君,张飞,邹春阳.冰水混合间接换热系统中换热器 参数试验[J]_农业工程学报,201 1,27(1 1):126—129. Zhou Fujan,Zhang Fei,Zou Chunyang.Experiment on heat exchanger parameters of indirect heat transfer system by mixed ice water[J].Transactions of the Chinese Society of Agricultural Engineering(Transactions of the CSAE),201 1, 27(1 11:126—129.(in Chinese with English abstract) [2] 张飞,周福君.自然冷资源保鲜库自控系统设计及应用[J]. 东北农业大学学报,2010,41(12):109一l12. Zhang Fei,Zhou Fujtin.Design and application of an automatic control system on vegetable freshening with natural cool resources[J].Journal of Northeast Agricultura1 Universiyt,2010,41(12):109—1 12.(in Chinese with English abstract) [3] 刘晓辉,鲁墨森,王淑贞,等.小型冷库多效冷凝制冷机组 的能耗及节能分析[J】.农业工程学报,2010,26(6):103—107. Liu Xiaohui,Lu Mosen,Wang Shuzhen,et a1.Analysis of energy consumption and energy conservation of multi.effect condensed refrigeration unit in small cold storage[J]. Transactions of the Chinese Society of Agricultural Engineering(Transactions of the CSAE),2010,26f6):103— 107.(in Chinese with English abstract) [4] 郑传祥,卓传敏.大型速冻设备不同结构蒸发器的传热性 能比较[J].农业工程学报,2006,22(8):l1 1一l15. Zheng Chuanxiang,Zhuo Chuanmin.Comparative research on the heat transfer efHciency of evalc’orators with diflferent structures used in a large quick.freeze plnat[J].Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE1,2006,22(81:l1 1一ll 5。(in Chinese with English abstract) f51 Wang Chichuan.A survey of recent口atents offin.and.utbe heat exchangers from 2001 to 2009[J].Intemational Journal ofAir.Conditioning andRefrigeration,2010,18(11:1—13. [6】 Zhang Jiehai,Jaydeep K,Manglik R M.Effect of fin waviness and spacing on the lateral vortex structure and laminar[J].Journal of Heat and Mass Transfer,2004,47(8/9): 1719一l730. 『71 Joardar A,Jacobi A M.Heat transfer enhancement by wingler-type vortex generator arrays in compact plain.fin.and.tube heat exchangers[J].International Journal ofRefrigeration,2008,31(1):87—97. f81 Chu P,He Y L.Three.dimensional numerical study of lfow and heat transfer enhancement using vortex generators in ifn-and-tube heat exchangers[J].Journal of Heat Transfer, 2009,131f91:091903—1.091903-8. [93 Mi Sander Mon.UMch Gross.Numerical study of ifn-spacing effectsin annularfinnedtube heattransfer exchangers『J].Int J Heat Mass Transfer,2004,47(8/9 :1953—1964. [1O】蒋翔,朱冬生,唐广栋,等.来流速度分布对蒸发式冷凝器 性能的影响[J].华南理工大学学报,2006,34(8):55—60. Jiang Xiang,Zhu Dongsheng,Tang Guangdong,et a1.Effect of inlet air velocity distribution on performance of evaporative condenser[J].Joumal of South China Universiyt of Technology,2006,34f8):55—60.(in Chinese with English absrtact) [11】代善良迎面风速对直接空冷凝汽器流动换热特性的影响[D]. 哈尔滨:哈尔滨工业大学,2013:9—12. Dai Shanlang.Influence of Hcad Wind Velocity on Flow and Heat Transfer Performance of Direct Air—cooled Condenser[D].Harbin:Harbn Instiutte of,Technology.2013: 9—12.(in Chinese with English abstract) 『121 Meyer C J.Numerica¨nvestigation of the eflfect of inlet flow idstortions on forced draught air cooled heat exchanger performance[J].Applied Thermal Engineering,2005,25: 1634—1649. f131 Kaiser A S,Lucas M,Viedma A,et a1.Numerical model of evaporative cooling processes in a new type of cooling tower[J].International Journal Heat Mass Transfer,2005, 48f51:986—999. 第13期 周福君等:冷库冰水混合间接换热器的传热与流动特性 285 ing Guide Release 【14】 Ansys Inc.ANSYS CFX.Solver Model[18】张艳霞,张红,陶汉中.基于场协同理论的管翅式换热器 14.5『M1.New York,Ansys Inc.2013. nc.ANSYS CFX.Reference Guide Release 14.5『M]. 【15】 Ansys INew York,Ansys Inc.2013. 翅片效率的数值模拟研究【J]_建筑科学,201 1,27(10): 98—101. Zhang Yanxia,Zhang Hong,Tao Hanzhong.Numerica1 simulation on fin eficifency oftube..and..ifn heat exchanger [16】 杜鹃,钱作勤,陈昌,等.多种平直开缝翅片换热特性的数 值研究【J】.南京航空航天大学学报,2014,46(4):612—617. Du Juan.Qin aZuoqin,Chen Chang,et a1.Numerical study on heat trnsafer characteristies of plate slit ifns[J].Journa1 of Nanjing University of Aeronautics&Astronautics.2014. 46(41:612--617.(in Chinese with English abstract) Yan【17] g L J,Du X Z,Yang Y P.Space characteristies of the thermal performance for air-cooled condensers at ambient based on ifeld synergy principle[J].Building Science,201 1, 27(10):98—1O1.(in Chinese with English abstract) [19]Zhang Bo, Jinsheng,Zuo Jixue.Compressible fluid lfow ielfd synergy principle and its application to drag reduction in variable—cross-section pipeline[J].Intemational Journal of HeatanMassTransfer,201 4.77:】O95一】】0】. wends[J].Intemational Journal of Heat and Mass Transfer, 201 1.54(15/16):3109—3119. 【201 Habchi C,Lemenand T,Valle D D,et a1.Entropy production and field synergy princiFlle in turbulent vertical lfows[J].Int J Thermal Sci,201 1.50:2365—2376. Heat transfer and flow performance of indirect heat exchanger by mixed ice water based on natural cold resource Zhou Fujun,Pan Xiaoli,Wang Wenming (Engineering College ofNortheast Agricultural University,Harbin 1 50030,China) Abstract:According to the climatic characteristics of long cold winter days in the northern area.the storage of natural cold resources from winter are used for cooling in summer to achieve the goals of conserving energy and reducing carbon emission. To address the issues with regard to controlling the temperature and humidity of environment as well as the usage time of cold resources are short when natural cold resources are used for me storage and preservation of agricultura1 product through blowing the natural air into the ice storage directly,the ice.water mixture was used as the heat exchange medium and air quality was improved by means of indirect heat exchanger with inner loop cooling.The process route of freezing storage-release cold energy by mixing ice and water-exchange heat indirectly-temperature and humidity independently was proposed in this study.The laboratory used for the experiment was a closed storehouse with a size of2 m x 2 m×2 m.The ice water at 0.5℃as coolnta lfowed rom ftop to bottom in the ifnned ube theat exchanger by use ofa water pump.The hot air of environment crossed fumed tube under the action of the fan,then the water temperature rose when the cold water flowed through the copper tube wall to absorb heat of he ttube outer surface and the fin surface.The cooling air was blown into the storage,the mixture of cooling air and fresh outdoor air exchanged heat in heat exchanger.The measuring element used in the experiment can be connected with the computer,and data acquisition using RMA4ll remote input capture module,which can be carried out in 1 6 channels of analog data acquisition.The data output adopted the distal RM4024 analog output module. which carl realize the output of oufr voltage signals,achieving real time communication between the host computer and data acquisition and output module,through the RS485 serial port.Temperature and humidiy acquitsition adopted Ptl 00 temperature sensor and humidity sensor series,respectively.The instrument used in the test was corrected precisely prior to the experiment in order to meet the test requirements.The average value ofthe air flow was determined by the measurement ofthe ifve points of heat exchanger outlet section.The pump flow rate nd aiar lfow rate were adjusted by frequency converter.The values of CFD were similr to tahe value of experiments。and he error was ltess than 1 5%.Then the results of the experiments were used to validate he tsimulation mode1.The experiment showed that he thead wind velociy thad a greater influence on he tperformance of heat exchanger.The heat transfer coe伍cient and the pressure drop increased by 1 33%and 428%respectively 。with the increase of the he:ad wind velociy.Howevert the increasing trend of heat transfer coeficifent became slow as the ncrieasing ofwind speed.When he thead wind velociy twas within the scope of 1.5 to 3.5 rn/s,the average ifeld synergy angles increased by l 2%and synergistic degree decreased.When the wind speed reached 3.5 rn/s,the field synergy angles hardly changed with wind speed.The scope of he bestt head wind velociy wast between 2.5.3 rn/s.The air inlet direction has significant impact on air distribution in the heat exchangen The air inlet direction could affect the heat transfer performance because too high or too low would produce eddy current and the uneven distribution of air flow.The results of the uniorfm wall temperature numerical simulation had a deviation wiⅡ1 he expertiments.The cooling capaciy itncreased bv 70.6%when he aitr inlet direction ncreased from一45 to 30℃.Tihe heat exchanger had a better performance when the air in1et direction was 3O℃. Key words:heat transfer;ice;cold storage;natural cold resources;tube.and.fin heat exchanger;flat fin;numerical simulation; ield fcoordination