报警号 报警信息

3000 Text Not Received (ANL <- DPR) (A)[A]3001 Text Not Received (UNT <- SMP) (A)[A]3002 Text Not Received (SMP <- UNT) (A)[A]

3003 DPR Communication Error (A, B, C, D, E, F, G, H)[A, B, C, D, E]3004 SMP Communication Error (A, B, C, D, E, F, G, H)[A, B, C, D, E]3005 Unit Communication Error (A, B, C, D, E, F, G, H)[A, B, C, D, E]3006 Text ID Information Unmatched (A, B, C, D, E, F)[A]3007 Text Receive Error (A, B)[A]

3020 Distributed Control Primary Station Error (A, B, C, D, E, F, G, H)[A, B, 3021 Distributed Control Secondary Station Error (A, B, C, D, E, F, G, H)[A, B3022 Motor Controller Error (A, B, C, D, E, F, G, H)[A, B, C, D, E]

3023 Barcode Reader Communication Error (A, B, C, D, E, F, G, H)[A, B, C, D, E3024 I/O Control Error (A, B, C, D, E, F, G, H)[A, B, C, D, E]

3100 Inner S Transfer Unit (FA01) Error (Up-Down) (A, B, C)[A, B, C, D, E]3101 Inner S transfer unit (FA01) Error (Up-Down) (A, B, C)[A, B, C, D, E]3102 Inner S Transfer Unit (FA01) Error (Rotation) (A, B, C)[A, B, C, D, E]3103 Inner S Dispenser Unit (SA-S-IN) Error (A)[A, B, C, D, E]

3104 Inner S Inside Wash Dispenser Unit (SA-W-IN) Error (A)[A, B, C, D, E]3110 Outer S Transfer Unit (FA11) Error (Up-Down) (A, B, C)[A, B, C, D, E]3111 Outer S Transfer Unit (FA11) Error (Up-Down) (A, B, C)[A, B, C, D, E]3112 Outer S Transfer Unit (FA11) Error (Rotation) (A, B, C)[A, B, C, D, E]3113 Outer S Dispenser Unit (SA-S-OUT) Error (A)[A, B, C, D, E]

3114 Outer S Inside Wash Dispenser (SA-W-OUT) Error (A)[A, B, C, D, E]3115 S Transfer Unit (FA01/FA11) Initialize Error [A]3120 Cuvette Wash Unit (FB) Error (A)[A, B, C, D, E]

3125 Cuvette Wash Water Dispensing Disabled (A)[A, B, C, D, E]3130 R1/S Mixing Unit (FC01) Error (Up-Down) (A)[A, B, C, D, E]3131 R1/S Mixing Unit (FC01) Error (Rotation) (A)[A, B, C, D, E]3132 R1/S Mixing Unit (FC01) Error (Mixing) (A)[A, B, C, D, E]3135 R2 Mixing Unit (FC11) Error (Up-Down) (A)[A, B, C, D, E]3136 R2 Mixing Unit (FC11) Error (Rotation) (A)[A, B, C, D, E]3137 R2 Mixing Unit (FC11) Error (Mixing) (A)[A, B, C, D, E]

3140 Inner R1 Transfer Unit (FD01) Error (Up-Down) (A, B, C)[A, B, C, D, E]3141 Inner R1 Transfer Unit (FD01) Error (Up-Down) (A, B, C)[A, B, C, D, E]3142 Inner R1 Transfer Unit (FD01) Error (Rotation) (A, B, C)[A, B, C, D, E]3143 Inner R1 Dispenser Unit (SA-R1-IN) Error (A)[A, B, C, D, E]

3144 Inside Wash Water Dispensing Disabled at Inner R1 Transfer (A)[A, B, C, D3150 Outer R1 Transfer Unit (FD11) Error (Up-Down) (A, B, C)[A, B, C, D, E]3151 Outer R1 Transfer Unit (FD11) Error (Up-Down) (A, B, C)[A, B, C, D, E]3152 Outer R1 Transfer Unit (FD11) Error (Rotation) (A, B, C)[A, B, C, D, E]3153 Outer R1 Dispenser Unit (SA-R1-OUT) Error (A)[A, B, C, D, E]

3154 Inside Wash Water Dispensing Disabled at Outer R1 Transfer (A)[A, B, C, D3155 R1 Transfer Unit (FD01/FD11) Initialize Error [A]

3160 Inner R2 Transfer Unit (FD21) Error (Up-Down) (A, B, C)[A, B, C, D, E]3161 Inner R2 Transfer Unit (FD21) Error (Up-Down) (A, B, C)[A, B, C, D, E]3162 Inner R2 Transfer Unit (FD21) Error (Rotation) (A, B, C)[A, B, C, D, E]3163 Inner R2 Dispenser Unit (SA-R2-IN) Error (A)[A, B, C, D, E]

31 Inside Wash Water Dispensing Disabled at Inner R2 Transfer (A)[A, B, C, D3170 Outer R2 Transfer Unit (FD31) Error (Up-Down) (A, B, C)[A, B, C, D, E]3171 Outer R2 Transfer Unit (FD31) Error (Up-Down) (A, B, C)[A, B, C, D, E]3172 Outer R2 Transfer Unit (FD31) Error (Rotation) (A, B, C)[A, B, C, D, E]3173 Outer R2 Dispenser Unit (SA-R2-OUT) Error (A)[A, B, C, D, E]

3174 Inside Wash Water Dispensing Disabled at Outer R2 Transfer (A)[A, B, C, D3175 R2 Transfer Unit (FD21/FD31) Initialize Error [A, B, C, D, E]3180 R1 Refrigerator Unit (DA01) Error (A)[A, B, C, D, E]3181 R2 Refrigerator Unit (DA11) Error (A)[A, B, C, D, E]3190 Cuvette Wheel (GA) Error (Rotation) (A)[A, B, C, D, E]3192 Sample Shutter Unit (CJ01) Error (A)[A, B, C, D, E]

3200 Photometry Controller Error 1 (A, B, C, D, E, F, G, H)[A]

3201 Photometry Controller Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E]3205 Thermal Control Error 1 (A, B, C, D, E, F, G, H)[A]

3206 Thermal Control Error 2 (A, B, C, D, E, F, G, H)[A, B, C, D, E]3210 Cooling Unit (DB) Error (A)[A]

3212 Temperature Controlled Bath Unit (GA) Temp. out of Range [A]3214 Cooling Unit (DB) Error (A)[A]

3215 Sample Probe (FA) Error (Liquid Sensor) (A, B)[A, B, C, D, E]3216 Sample Probe (FA) Error (Liquid Sensor) (A, B)[A, B, C, D, E]3217 Sample Probe (FA) Error (Clot Sensor) (A, B)[A, B, C, D, E]

3220 R1 Reagent Probe (FD01/FD11) Error (Liquid Sensor) (A, B)[A, B, C, D, E]3221 R1 Reagent Probe (FD01/FD11) Error (Liquid Sensor) (A, B)[A, B, C, D, E]3223 R2 Reagent Probe (FD21/FD31) Error (Liquid Sensor) (A, B)[A, B, C, D, E]3224 R2 Reagent Probe (FD21/FD31) Error (Liquid Sensor) (A, B)[A, B, C, D, E]3227 Second Washing Well Pouring Error (A)[A, B, C, D, E]3228 Second Washing Well Draining Error [A, B, C, D, E]3230 Sample Short (A, B, C, D, E, F, G, H, I, J, K)[A] dl[u ]

3232 Sample Probe Short Aspiration (A, B, C, D, E, F)3233 Sample Probe Detergent Short (A)[A]3234 Sample Probe Detergent Empty (A, B)[A]3235 Sample Probe Detergent Empty (A, B)[A]3236 Sample Probe W2 Detergent Empty (A)[A]3237 Sample Pre-Diluent Short (A)[A]

3238 Sample Pre-Diluent Run Out (A, B, C, D, E, F, G)[A]3239 Sample Pre-Diluent Run Out (A, B, C, D, E, F, G)[A]

3240 Sample Pre-Diluent Diluent Empty (A, B, C, D, E, F, G, H, I, J)[A]3241 Sample Pre-Diluent Diluent Empty (A, B, C, D, E, F, G, H, I, J)[A]3245 R1 Reagent Short (A, B)[A]

3246 R1 Reagent Run Out (A, B, C, D, E, F, G)[A]3247 R1 Reagent Run Out (A, B, C, D, E, F, G)[A]

3248 R1 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K)[A]3249 R1 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K)[A]3250 R1 Probe Detergent Short (A)[A]3251 R1 Probe Detergent Empty (A, B)[A]3252 R1 Probe Detergent Empty (A, B)[A]3253 R1 Probe W2 Detergent Short (A)[A]

3254 R1 Probe cold water Supply Error (A)[A]3255 R2 Reagent Short (A, B)[A]

3256 R2 Reagent Run Out (A, B, C, D, E, F, G)[A]3257 R2 Reagent Run Out (A, B, C, D, E, F, G)[A]

3258 R2 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K)[A]3259 R2 Reagent Empty (A, B, C, D, E, F, G, H, I, J, K)[A]3260 R2 Probe Detergent Short (A)[A]3261 R2 Probe Detergent Empty (A, B)[A]3262 R2 Probe Detergent Empty (A, B)[A]3263 R2 Probe W2 Detergent Short (A)[A]

32 R1 Probe cold water Supply Error (A)[A, B, C, D, E]

3270 Detergent Empty [A]3271 Detergent Empty [A]3272 Detergent Overflow [A]3273 Detergent Overflow [A]

3275 Vacuum Tank Weak Pressure [A]3276 Vacuum Tank Full [A]

3277 Concentrated waste water tank Full [A]3278 Washing waste water tank Full [A]3280 Detergent Generation Unavailable [A]

3285 Photometer Unit (GB) Error (A)[A, B, C, D, E]3286 Photometric Data Error (A, B)[A]3287 Lamp Off Error [A]

3288 Lamp Dark Error (A)[A]

3295 R1 Reagent Refrigerator Cover Open [A]3296 R1 Reagent Refrigerator Cover Open [A]3297 R2 Reagent Refrigerator Cover Open [A]3298 R2 Reagent Refrigerator Cover Open [A]

3300 Rack Loading Unit (CB) Pusher Error (A, B)[A, B, C, D, E]3301 Rack Loading Unit (CB) Receiver Error (A, B)[A, B, C, D, E]3302 ID Reader Lever 1 (CC1) Error (A)[A, B, C, D, E]3303 ID Reader Lever 2 (CC2) Error (A)[A, B, C, D, E]

3304 Rack Buffer Unit (CD) Error (X-Axis) (A)[A, B, C, D, E]

3305 Rack Buffer Unit (CD) Lever Error (Up-Down) (A)[A, B, C, D, E]3306 Rack Buffer Unit (CD) Error (Y-Axis) (A)[A, B, C, D, E]3307 Passing Lane Rack Feed Unit (CE) Error (A)[A, B, C, D, E]3308 Dispensing Lane Rack Feed Unit (CE) Error (A)[A, B, C, D, E]3309 Unloading Rack Feed Unit (CF) Error (A)[A, B, C, D, E]3310 Rack Unloading Unit (CG) Lever Error (A)[A, B, C, D, E]3312 Recovery Rack Feed Unit (CL) Error (A)[A, B, C, D, E]3313 ANL Passing Lane Belt (CH01) Error (A, B)[A, B, C, D, E]3314 ANL Passing Lane Lever (CH02) Error (A, B)[A, B, C, D, E]3315 ANL Dispensing Lane Belt (CH01) Error (A, B)[A, B, C, D, E]3316 ANL Dispensing Lane Lever 1 (CH01) Error (A, B)[A, B, C, D, E]

3317 ANL Dispensing Lane Lever 1 (CH01) Retraction Error (A, B)[A, B, C, D, E]3318 ANL Dispensing Lane Lever 2 (CH01) Error (A, B)[A, B, C, D, E]

3319 ANL Dispensing Lane Lever 2 (CH01) Retraction Error (A, B)[A, B, C, D, E]3320 ANL Dispensing Lane Stopper (CH01) Error (A, B)[A, B, C, D, E]3321 ANL Rack Feed Belt (CH01) Error (A, B)[A, B, C, D, E]3322 ANL Recovery Lane Belt (CH11) Error (A, B)[A, B, C, D, E]3323 ANL Lane Changer Unit (CK) Error (A, B)[A, B, C, D, E]3324 ANL Lane Change Stopper (CK) Error (A, B)[A, B, C, D, E]3325 ISE Passing Lane Belt (CM01) Error (A)[A, B, C, D, E]3326 ISE Passing Lane Lever (CM01) Error (A)[A, B, C, D, E]3327 ISE Dispensing Lane Belt (CM01) Error (A)[A, B, C, D, E]3328 ISE Dispensing Lane Lever (CM01) Error (A)[A, B, C, D, E]3329 ISE Recovery Lane Belt (CM11) Error (A)[A, B, C, D, E]3331 Passing Lane Rack Step Error (A, B)[A, B, C, D, E]3332 Dispensing Lane Rack Step Error (A, B)[A, B, C, D, E]3333 Passing Lane Rack Jam (A, B)[A, B, C, D, E]3334 Dispensing Lane Rack Jam (A, B)[A, B, C, D, E]3335 Recovery Lane Rack Jam (A, B)[A, B, C, D, E]

3336 Passing Lane Rack Step Prohibition Signal Detected (A)[A, B, C, D, E]3337 Dispensing Lane Rack Step Prohibition Signal Detected (A)[A, B, C, D, E]3338 Sampler Unit Rack Jam (A)[A, B, C, D, E]

3340 Rack Type Reading Error (A)[A]3341 Rack Type Unmatched (A, B, C)[A]3342 Rack Feed Error (A, B, C)[A]

3343 Rack Step Synchronization Error (A, B, C, D, E, F)[A, B, C, D, E]3344 Rack ID Barcode Reading Error (A, B, C)[A]3345 RB Incomplete3346 ACAL Incomplete3347 QC Incomplete

3349 Rack Set Error (A)[A]

3350 Rack Buffer Cover Open [A]3351 Rack Buffer Cover Open [A]3352 Rack Loading Stop [A]3353 Rack Loading Stop [A]3354 No Rack [A]

3355 Rack ID Barcode Reading Error (A)3356 Priority Rack Cover Open [A]3357 No Priority Rack [A]

3358 Recovery Rack ID Barcode Reading Error (A, B)[A]3360 Power Failure Detect [A]

3361 Sample ID Barcode Reading Error (A)[A]3362 Maker Setting Parameter Error (A, B)[A]3363 Unit Communication Error (A)[A]3365 Replenishment Detergent Short [A]3366 Failed to Start Analysis3370 Cup Detect Error (A)

3371 Passing Lane Initialization Error (A)[A]3372 Dispensing Lane Initialization Error (A)[A]

3373 Rack Unloading Unit Full or No Rack Unloading Tray (A)[A]3374 No Priority Rack (A)[A]

3375 Rack Existence on Passing Lane Feed Unit [A]3376 Rack Existence on Dispensing Lane Feed Unit [A]3377 Rack Existence on Recovery Rack Feed Unit [A]3378 Rack Unloading Unit Full (A)[A]

3379 Rack Unloading Unit Full or No Tray [A]3380 No Rack Unloading Tray (A)[A]

3381 Rack Existence at ID Reading Position (A)[A]3382 Rack Existence on Rack Transfer Unit (A)[A]3383 Rack Existence on Unloading Rack Feed Unit [A]3384 Rack Existence on Rack Buffer Unit (A)[A]3385 Rack Existence on ANL Passing Lane (A, B)[A]3386 Rack Existence on ANL Dispensing Lane (A, B)[A]3387 Rack Existence on ANL Recovery Lane (A, B)[A]3388 Rack Existence on ISE Passing Lane (A)[A]33 Rack Existence on ISE Dispensing Lane (A)[A]3390 Rack Existence on ISE Recovery Lane (A)[A]

3391 Rack Illegal Setting on Priority Rack Loading Unit (A)[A]3392 No Rack Unloading Tray (A)[A]3393 No Rack Loading Tray

3401 LA rack feed unit (CN) Error (A)[A, B, C, D, E]3402 Rack unloading unit (CP) Error (A)[A, B, C, D, E]3406 Rack unloading unit (CP) Full (A)[A]3407 No Rack Unloading Tray (A)[A]

3408 Rack ID Barcode Reading Error (A, B, C)[A]

3409 LA rack carry-out operation is disabled (A, B)[A]

3410 Rack unloading operation is disabled

3411 Rack Illegal Setting on the lanes connected to LA (A)[A]3416 LA rack carry-in procedure Error (A)[A]3417 LA rack carry-out procedure Error (A)[A]3419 LA rack carry-out procedure Error (A)[A]3421 Rack Jam at carry-in from LA (A)[A]3422 Rack Jam at carry-out to LA (A)[A]

3501 ISE Monitor Communication Error (A, B)[A]

3502 ISE Sample Transfer Unit (FA21) Error (Up-Down) (A, B, C)[A, B, C, D, E]3503 ISE Sample Transfer Unit (FA21) Error (Rotation) (A, B, C)[A, B, C, D, E]3504 ISE Sample Probe (FA21) Level Sensor Error (A, B)[A, B, C, D, E]3505 ISE Sample Dispenser (SA21) Error (A)[A, B, C, D, E]

3506 ISE Sample Probe Inside Wash Dispenser (SA31) Error (A)[A, B, C, D, E]3507 ISE Sample Dispenser Pressure Sensor (IAS11) Error (A)[A, B, C, D, E]3508 ISE Buffer Dispenser (SA01) Error (A, B)[A, B, C, D, E]3509 ISE Buffer Dispenser (SA01) Error (A, B)[A, B, C, D, E]3510 ISE Sample Pot Level Sensor Error (A, B)[A, B, C, D, E]3511 ISE Sample Pot Level Sensor Error (A, B)[A, B, C, D, E]3512 ISE Sample Pot Overflow (A, B)[A, B, C, D, E]3513 ISE Sample Pot Overflow (A, B)[A, B, C, D, E]3514 ISE Analog Power Supply Error (A, B)[A]3515 ISE Analog Power Supply Error (A, B)[A]3516 ISE Sample Syringe Priming Incomplete [A]3517 ISE Calibrator Illegal Setting [A]3518 ISE Drain Flow Cell Incomplete [A]

3519 ISE Data Controller Error (A, B, C, D, E)[A]3520 ISE Data Controller Error (A, B, C, D, E)[A]3521 ISE Data Controller Error (A, B, C, D, E)[A]3522 ISE Mixing Motor Error (A, B)[A, B]3523 ISE Mixing Motor Error (A, B)[A, B]

3524 ISE Roller Pump for MID Standard Solution Dispensing Error (A)[A, B]3525 ISE Roller Pump for MID Standard Solution Dispensing Error (A)[A, B]3526 ISE Roller Pump for Mixture Aspiration Error (A)[A, B]3527 ISE Roller Pump for Mixture Aspiration Error (A)[A, B]3528 ISE Controller Error (A)[A, B]3529 ISE Controller Error (A)[A, B]

3530 ISE Sample Short (A, B, C, D, E, F, G, H, I, J)[A]3531 ISE Sample Probe Detergent Short (A)[A]

3532 ISE Sample Probe Detergent Running Out (A)[A]3533 ISE Sample Probe Detergent Running Out (A)[A]

3534 ISE Sample Probe Clot detect (A, B, C, D, E, F, G)[A]

3535 Sample Probe False Aspiration Detected (A, B, C, D, E, F)[A]3536 ISE Buffer Solution Short (A)[A]

3537 ISE MID Standard Solution Short (A)[A]3538 ISE Reference Solution Short (A)[A]3539 ISE Cleaning Solution Short [A]

3540 IES Serum Standard Solution H Short [A]3541 IES Serum Standard Solution L Short [A]3542 IES Urine Standard Solution H Short [A]3543 IES Urine Standard Solution L Short [A]3544 ISE Na Selectivity Check Solution Short [A]3545 ISE K Selectivity Check Solution Short [A]3546 ISE Serum CRS Standard Solution H Short [A]

3547 ISE Serum CRS Standard Solution M Short [A]3548 ISE Serum CRS Standard Solution L Short [A]3549 ISE Urine CRS Standard Solution H Short [A]3550 ISE Urine CRS Standard Solution M Short [A]3551 ISE Urine CRS Standard Solution L Short [A]3560 ISE Cover Open [A]3561 ISE Cover Open [A]

3570 Check ISE Sample Probe Tip [A]

3571 Concentration Calculation Disabled (A)[A]3572 Concentration Calculation Disabled (A)[A]3573 ISE Sequence Error (A, B, C, D, E)[A]3574 ISE Sequence Error (A, B, C, D, E)[A]

3575 ISE MID Standard Solution Stability Error ( pre-calibration ) (A)[A]3576 ISE MID Standard Solution Stability Error ( pre-calibration ) (A)[A]

3577 ISE MID Standard Solution Stability Error ( during calibration ) (A, B)[A3578 ISE MID Standard Solution Stability Error ( during calibration ) (A, B)[A3579 IES Serum Standard Solution H Stability Error (A)[A]3580 IES Serum Standard Solution H Stability Error (A)[A]3581 IES Serum Standard Solution L Stability Error (A)[A]3582 IES Serum Standard Solution L Stability Error (A)[A]3583 IES Urine Standard Solution H Stability Error (A)[A]3584 IES Urine Standard Solution H Stability Error (A)[A]3585 IES Urine Standard Solution L Stability Error (A)[A]3586 IES Urine Standard Solution L Stability Error (A)[A]3587 Na Concentration Low Error (A)[A]3588 Na Concentration Low Error (A)[A]35 Na Concentration Low Error (A)[A]

3600 Multi Reagent Switch (A, B, C, D, E)[A]3601 No Reagent Bottle for RB/ACAL (A, B, C)[A]3602 Reagent Short for RB/ACAL/QC (A, B, C)[A]3604 Reagent Refrigerator On Use [A]

3605 RB/ACAL Sample Diluent Short (A, B)[A]3606 Check the Tip of Sample Probe (A)[A]3607 Check the Tip of R1 Reagent Probe (A)[A]3608 Check the Tip of R2 Reagent Probe (A)[A]3609 Sample Syringe Prime Incomplete [A]

3610 Reagent Bottle Illegal Setting (A, B, C)[A]3611 Sample Probe Periodic Cleaning (A, B, C)[A]3620 Reagent ID Barcode Error (A, B)[A]3630 DI Water Short [A]3631 DI Water Empty [A]3632 DI Water Empty [A]3633 DI Water Overflow [A]

3634 DI Water Supply Unavailable [A]3635 DI Water Supply Unavailable [A]3636 Master Detergent Empty [A]3637 Master Detergent Empty [A]

3638 Master Detergent Supply Unavailable [A]3639 Master Detergent Overflow [A]

30 Reagent Probe Position Illegal (A, B)[A]

31 Photometry Error During a Cuvette Wash (A, B, C)[A]3901 ANL Program Error (A, B, C)[A, B]

3902 ANL Program Error 1 (A, B, C, D)[A, B]

3903 ANL Program Error 2 (A, B, C, D, E)[A, B]3904 ANL Program Error 3 (A, B, C, D, E, F)[A, B]3905 ANL Mechanical Error (A, B, C)[A, B, C, D, E]

3906 ANL Mechanical Error 1 (A, B, C, D)[A, B, C, D, E]3907 ANL Mechanical Error 2 (A, B, C, D, E)[A, B, C, D, E]3908 ANL Mechanical Error 3 (A, B, C, D, E, F)[A, B, C, D, E]3909 ANL Debug Information 1 (A, B, C, D, E, F, G, H, I, J)3910 ANL Debug Information 2 (A, B, C, D, E, F)[A, B]

3911 ANL Debug Information 3 (A, B, C, D, E, F, G, H, I, J)3912 ANL Debug Information 4 (A, B, C, D, E, F, G, H, I, J)5001 ANL PROGRAM DOWNLOAD COMPLETED5002 INITIALIZE5003 WARM UP5004 STANDBY

5005 MEASURE START5006 LAST RACK

5007 SHIFT TO PAUSE

5008 SHIFT TO STOP MODE5009 PAUSE5010 STOP

5011 SYSTEM END5012 W1 START (A)5013 W2 START (A)

5014 PHOTOCAL START (A)5015 W1 END (A)5016 W2 END (A)

5017 PHOTOCAL END (A)

5018 PHOTOCAL FAILURE (A, B)5020 MEASURE END5021 SHIFT TO STOP

5022 W1 FAILURE (A, B)5023 W2 FAILURE (A, B)

5028 BLANK INDEX DELETED (A)

5029 BLANK REACTION DATA DELETED (A)5030 BLANK QC INDEX DELETED (A)5031 INDEX UPDATED (A)5032 INDEX DELETED (A)

5033 REACTION DATA DELETED (A)5034 QC INDEX DELETED (A)

5041 ISE CALIBRATION START (A)

5042 ISE SELECTIVITY CHECK SATRT (A)5043 ISE CRS CALIBRATION START (A)5044 ISE CLEANING START (A)

5045 ISE CLEANING ENHANCED START (A)5046 ISE CALIBRATION END (A)

5047 ISE SELECTIVITY CHECK END (A)5048 ISE CRS CALIBRATION END (A)5049 ISE CLEANING END (A)

5050 ISE CLEANING ENHANCED END (A)5051 POWER ON

5090 LOGIN (A, B)5091 LOGOUT (A, B)

5092 LOGIN FAILURE (A)

5093 PASSWORD CHANGE FAILURE (A)

5101 NO REAGENT BOTTLE (A, B, C, D, E)5103 REAGENT ID READ ERROR (A, B, C)5104 REAGENT ID READ ERROR (A, B, C)

5105 REAGENT ID NOT DEFINED (A, B, C, D)5106 ILLEGAL REAGENT TYPE (A, B, C)

5107 R2 REAGENT FOUND IN THE R1 REFRIGERATOR (A, B, C, D)5108 R1 REAGENT FOUND IN THE R2 REFRIGERATOR (A, B, C, D)5109 ILLEGAL BOTTLE TYPE (A, B, C)

5110 ILLEGAL REAGENT POSITION (A, B, C)5111 REAGENT EXPIRED (A, B, C, D)

5112 DIFFERENT LOT NO. REAGENT FOUND (A, B, C, D)5114 REAGENT TYPE CONVERTED (A, B, C)5115 BOTTLE TYPE CONVERTED (A, B, C)

5116 THE REAGENT VOLUME EXCEEDED THE LIMIT (A, B, C, D, E)5201 PHOTOCAL DATA ERROR (A)

5202 CUVETTE MEAN CHECK ERROR (A)5203 PHOTOCAL LAMP CHECK ERROR (A)

5251 INCUBATION BATH TEMPERATURE HIGH (A)5252 INCUBATION BATH TEMPERATURE LOW (A)

5253 REAGENT REFRIGERATOR TEMPERATURE HIGH (A)5254 REAGENT REFRIGERATOR TEMPERATURE LOW (A)5301 PANIC VALUE (A, B, C, D, E, F)

5302 HbA1c PRETREATMENT CHECK RANGE ERROR (A, B, C, D-E, F)5303 HbA1c% CALCULATION FAILED (A, B, C, D-E, F)5304 NO COLOR DATA (A, B, C, D-E, F)5305 NO BLANK DATA (A, B, C, D-E, F)5306 RB DATA ERROR (A, B, C, D, E, F)

5307 CALIBRATION FACTOR RANGE OVER (A, B, C, D, E, F)5308 CALIBRATION FACTOR RANGE UNDER (A, B, C, D, E, F)5309 CALIBRATION OD RANGE OVER (A, B, C, D, E, F)5310 CALIBRATION OD RANGE UNDER (A, B, C, D, E, F)5311 CALIBRATION ERROR (A, B, C, D, E, F)

5312 MULTIPOINT-CAL. OD SLOPE CHECK ERROR (A, B, C, D, E)5313 1/2 POINT-CAL. CORRECTION FACTOR ERROR (A, B, C, D, E)5314 QC DATA RANGE OVER (A, B, C, D, E, F)5315 QC DATA RANGE UNDER (A, B, C, D, E, F, G)

5316 QC DATA MULTI-RULE CHECK ERROR (A, B, C, D, E, F)5317 QC DATA DEVIATION CHECK ERROR (A, B, C, D, E, F, G)5318 ISE CRS CALIBRATION FAILED (A)

5319 HbA1c% LOT NO. UNMATCHED (A, B, C, D-E, F)

5320 REACTION PROFILE CHECK ERROR (A, B, C, D, E, F, G, H)5321 RATE REVERSE REACTION CHECK ERROR (A, B, C, D, E)5322 LINEARITY CHECK ERROR (A, B, C, D, E)

5323 REACTION PROFILE CHECK CONSECUTIVE JUDGEMENTERROR (A, B)

5401 NO SAMPLE CUP (A, B, C-D, E)5402 SAMPLE NOP (A, B, C-D, E)

5403 SAMPLE ID NOT FOUND (A, B, C-D, E)5404 NO TESTS REQUISITIONED (A, B, C-D, E)5405 MAXIMUM NUMBER OF SAMPLE (A, B, C-D, E)5406 SAMPLE NO. CALCURATE ERROR (A, B-C)

5407 BROKEN LABEL (A, B-C, D)

5408 SAMPLE ID READ ERROR (A, B-C)

5409 MEASURE COMPLETED FOR THE READ SAMPLE ID (A, B-C, D)5410 MEASURE COMPLETED FOR THE READ SAMPLE ID (A, B-C, D)5411 MEASURE COMPLETED FOR THE READ SAMPLE ID (A, B-C, D)5412 CAN NOT SET THE RACK IN THIS POSITION (A,B)5413 RB RACK SETTING ERROR (A)5414 ILLEGAL SAMPLE ID (A-B, C)

5415 NORMAL REPEAT NOT AVAILABLE (A-B, C)

5416 A part of test requisition has been deleted on Calibration or QCRack Requisition menu. (A,B)

5501 THERE IS A DANGER THAT THE WAVELENGTH IS NOTREGISTERED AS SET (A,B)

5502 CHECK RELATED PARAMETERS BY MISMATCHING TESTCODE (A, B, C <> D)

5503 CHECK RELATED PARAMETERS BY CHANGING TEST CODE (A, B, C -> D)5702 FILE NOT FOUND (A)5703 FILE WRITE ERROR (A)5751 PRINTER NOT SELECTED

5753 PART OF DATA IS NOT OUTPUT YET5754 PRINTER BUSY

6010 FAILED TO DELETE SAMPLE (A, B)

6020 FAILED TO REQUISTION BECAUSE OF MAXIMUM SAMPLE NO. (A, B-C,D)6024 NO REAGENT BLANK DATA (A, B, C-D, E)6025 NO CALIBRATION DATA (A, B, C, D, E)6031 ONLINE ERROR (A)(B C D E)6032 ONLINE FORMAT ERROR

6033 ONLINE ILLEGAL TEXT CODE (A)

6034 ONLINE ILLEGAL TEXT BLOCK No. (A<->B)6035 ONLINE ILLEGAL SAMPLE NO. (A B) C

6036 ONLINE ILLEGAL RACK NO. (A B C :D-E) F6037 ONLINE ILLEGAL SEX TEXT (A B :C) D6038 ONLINE ILLEGAL AGE/MONTH (A B :C D) E

6039 ONLINE ANALYSIS METHOD MISMATCH (A B :C<>D) E6040 ONLINE SAMPLE NO. MISMATCH (A B<>C D) E6041 ONLINE RACK NO. MISMATCH (A B :C-D<>E-F) G6042 ONLINE MISMATCH (A<>B)

6043 ONLINE TEST ITEM ERROR (A B) C D6044 ONLINE REPEAT ITEM ERROR (A B C)6100 ONLINE CONNECTION ERROR (A)(B C D)6101 ONLINE ERROR (A)(B C D) E

6102 ONLINE FORMAT ERROR (A B)(C) D6103 ONLINE SET UP ERROR (A B) C,D

6104 ONLINE REQUISITION INFORMATION RECEIVE ERROR (A B) C,D6111 ONLINE ILLEGAL ANALYSIS METHOD (A B) C,D6112 ONLINE ILLEGAL SAMPLE KIND (A B) C,D6113 ONLINE ILLEGAL SAMPLE TYPE (A B) C,D6114 ONLINE ILLEGAL SAMPLE NO. (A B) C,D6115 ONLINE ILLEGAL RACK NO. (A B:C-D) E,F6116 ONLINE ILLEGAL SEX TEXT (A B:C) D,E6117 ONLINE ILLEGAL AGE/MONTH (A B:C D) E,F

6118 ONLINE ILLEGAL PATIENT INFORMATION (A B:C D) E,F6119 ONLINE ILLEGAL SAMPLE ID (A B) C,D

6120 ONLINE SAMPLE ID MIXED (A<>B) C

6131 ONLINE ANALYSIS METHOD MISMATCH (A B<>C D) E,F6132 ONLINE SAMPLE KIND MISMATCH (A B<>C D) E,F6133 ONLINE SAMPLE TYPE MISMATCH (A B<>C D) E,F6134 ONLINE SAMPLE NO. MISMATCH (A B<>C D) E,F6135 ONLINE RACK NO. MISMATCH (A B:C-D<>E-F) G,H6136 ONLINE MISMATCH (A<>B) C

6151 ONLINE TEST ITEM ERROR (A B:C D) E,F6152 ONLINE REPEAT ITEM ERROR (A B) C

6153 ONLINE SAME SAMPLE ID ERROR (A B) C,D6161 ONLINE MAXIMUM SAMPLE NO. ERROR (A B) C,D6162 ONLINE SAMPLES REMAINING ERROR (A B) C,D6181 ONLINE PENDING TRANSFERS (A,B)

6182 SAMPLE REGISTRATION WAS DONE FOR HOST DIRECTION (A B) C,D6183 THERE IS UNPROCESSED SAMPLE AT CURRENT INDEX6500 PROService COMMUNICATION DATA ERROR (A B)6501 PROService COMMUNICATION BUFFER FULL (A B)6502 PROService COMMUNICATION TIMEOUT ERROR (A B)6503 PROService FILE TRANSFER FOLDER FULL (A)6504 FAILED TO LAUNCH THE BROWSER

6801 PrepLink COMMUNICATION ERROR (A, B)6802 CHEM ID NOT FOUND (A)

6803 CALCULATED TEST ERROR (A, B)

7001 SET CALIBRATION INFORMATION (A, B)

7002 OVER MAXIMUM SETTING OF SAMPLE BLANK (A)7003 NO REAGENT PARAMETER (A, B)

7011 SET CALIBRATION INFORMATION (A, B, C)7012 PERFORM CALIBRATION (A, B, C)

7013 SET CALIBRATOR INFORMATION (A, B, C)7014 UNIT OF CONC IS CHANGED. (A, B, C)8001 DPR-ANL COMMUNICATION ERROR (A, B)8002 DPR-ISE COMMUNICATION ERROR (A, B)8003 DPR-ANL COMMUNICATION TIMEOUT (A)8010 DIFFERENT VERSION OF FILE (A,B)8011 NO DATA FILE (A,B)8100 PRINTER ERROR

8200 ALARM NO. NOT FOUND (A)

8500 SAMPLE MANAGER EDIT (A, B, C, D)8501 QC DATA EDIT (A, B, C, D, E)

8502 OVERWRITTEN BY REPEAT (A, B, C, D)8503 RECALCULATE DATA (A,B,C)8504 DATA CORRECTION (A,B,C)8505 SAMPLE ID EDIT (A,B,C)8506 DATA UPDATE ERROR (A, B)

8507 A SAME SAMPLE ID EXISTS (A,B,C)

8508 RECALCULATE CALIBRATION DATA (A,B,C,D,E,F,G,H)9000 PROGRAM ERROR (・・・)9001 PROGRAM INF (・・・)9999 DEBUG INF (・・・)

翻译

分析仪未接收到控制电脑传送的文本控制单元未接收到样本信息传送的文本样本未接收到控制单元传送的文本控制电脑与生化仪之间通讯错误样本信息通讯错误控制单元通讯错误

文本标识信息不匹配(DPR与ANL之间)

文本接受错误

分布式控制第一级错误(生化仪内控制部分错误)分布式控制第二级错误(生化仪内控制部分错误)电机控制器错误

条码阅读器通讯错误 电路板输入输出错误

内圈样品传输单元?上下运动错误内圈样品传输单元上下运动错误内圈样品传输单元旋转运动错误内圈样品分配器(注射器)运行错误内圈内冲洗分配器(注射器)运行错误外圈样品传输单元上下运动错误外圈样品传输单元上下运动错误外圈样品传输单元旋转运动错误外圈样品分配器(注射器)运行错误外圈内冲洗分配器(注射器)运行错误样本传输单元初始化错误比色杯冲洗单元错误比色杯冲洗分配器失效

样品/R1搅拌单元上下运动错误样品/R1搅拌单元旋转运动错误样品/R1搅拌棒转动错误R2搅拌器上下运动错误R2搅拌器旋转运动错误R2搅拌棒转动错误

内圈R1试剂传输单元上下运动错误内圈R1试剂传输单元上下运动错误内圈R1试剂传输单元旋转运动错误内圈R1试剂针分配器错误

内圈R1试剂传输单元内冲洗分配器失效外圈R1试剂传输单元上下运动错误外圈R1试剂传输单元上下运动错误外圈R1试剂传输单元旋转运动错误外圈R1试剂传输单元分配器错误

外圈R1试剂传输单元内冲洗分配器失效R1试剂传输单元运动初始化错误内圈R2试剂传输单元上下运动错误内圈R2试剂传输单元上下运动错误内圈R2试剂传输单元旋转运动错误内圈R2试剂传输单元分配器错误

内圈R2试剂传输单元内冲洗分配器失效外圈R2试剂传输单元上下运动错误外圈R2试剂传输单元上下运动错误外圈R2试剂传输单元旋转运动错误外圈R2试剂传输单元分配器错误

外圈R2试剂传输单元内冲洗分配器失效R2试剂传输单元运动初始化错误R1试剂仓单元错误R2试剂仓单元错误比色杯轮盘错误样本推板单元错误光度测定控制器错误1光度测定控制器错误2加热器控制错误 1加热器控制错误 2制冷单元错误

孵育室温度超出范围制冷单元错误

样品针液面探测错误样品针液面探测错误样品针堵孔探测错误R1试剂针液面探测错误R1试剂针液面探测错误R2试剂针液面探测错误R2试剂针液面探测错误HBA1c冲洗池浇注错误HBA1c冲洗池排水错误样本量少样本针堵孔样品针吸样量少样品针清洗液少样品针清洗液空样品针清洗液空样品针W2清洗液空样品预稀释液少

样品预稀释液已使用完样品预稀释液已使用完样品预稀释液空样品预稀释液空R1试剂少

R1试剂已使用完R1试剂已使用完R1试剂空R1试剂空

R1试剂针清洗液少R1试剂针清洗液空R1试剂针清洗液空R1试剂针W2清洗液少R1试剂针冷却水供应错误R2试剂少

R2试剂已使用完R2试剂已使用完R2试剂空R2试剂空

R2试剂针清洗液少R2试剂针清洗液空R2试剂针清洗液空R2试剂针W2清洗液少R2试剂针水供应错误

清洗原液空清洗液空清洗液溢出清洗液溢出真空压力弱真空罐满浓废液罐满淡废液罐满

清洗液供应不足?光度测量单元错误光度测量数据错误光源灯关闭光源灯暗

R1试剂仓盖打开R1试剂仓盖打开R2试剂仓盖打开R2试剂仓盖打开

样品架固定单元进样错误样品架收集单元出架错误条码阅读器错误?条码阅读器错误?

缓冲区样品架水平移动错误缓冲区样品架推杆错误

缓冲区样品架上下移动错误样品架传输带错误

分配轨道样本架进样错误样品架卸载单元出架错误样本架卸载单元推板错误重测架进样错误分析仪传输带错误分析仪传输推板错误分析仪分配带错误分析仪分配带推板错误分析仪分配带推板错误分析仪分配带推板错误分析仪分配带推板错误分析仪分配带挡板错误

分析仪样品架进样轨道错误分析仪重测轨道错误分析仪变轨单元错误分析仪变轨单元挡板错误电解质传输轨道错误电解质传输轨道挡板错误电解质分配轨道错误电解质分配轨道挡板错误电解质重测轨道带错误传输轨道样本架运行错误分配轨道样本架运行错误传输轨道样本架卡住分配轨道样本架卡住重测轨道样本架卡住

探测到传输轨道进架禁止信号探测到分配轨道进架禁止信号样本单元卡架

样本架类型读取错误样品架类型不匹配样本架进样错误样本架进样同步错误样品架条形码阅读错误试剂空白未完成定标未完成质控未完成样品架设置错误

样品架缓冲区盖子打开样品架缓冲区盖子打开样本架进样停止样本架进样停止无样品架

样品架条码阅读错误急诊位置盖子打开无急诊架

重测样品架条码阅读错误出现电源故障

样本条形码阅读错误制造商参数设定错误通讯单元错误补充清洗液少开始检测失败探测比色杯错误传输轨道初始化错误分配轨道初始化错误

样本架卸载单元样本架满或者无卸载盘无急诊架

样本架滞留在传输轨道进样单元样本架滞留在分配轨道进样单元样本架滞留在重测轨道进样单元样本架卸载单元样本架满

样本架卸载单元样本架满或者无卸载盘无样本架卸载盘

样品架滞留在条码阅读器位置样本架滞留在样本架传输单元样本架滞留在卸载单元样本架滞留在缓冲区单元样本架滞留在分析仪传输轨道样本架滞留在分析仪分配轨道样本架滞留在分析仪重测轨道样本架滞留在电解质传输轨道样本架滞留在电解质分配轨道样本架滞留在电解质重测轨道急诊架进样单元样本架非法设置无样本架收集盘无样本架装载盘

自动化系统样本架进样单元错误样本架卸载单元错误样本架卸载单元满无样本架收集盘

样本架条形码阅读错误

自动化系统样本架出架无法完成

样本架卸载无法完成

仪器联接自动化时样本架非法设定自动化系统样本架进样程序错误自动化系统样本架出架程序错误自动化系统样本架出架程序错误样本架在进入自动化系统时卡架样本架从自动化系统卸载时卡架电解质控制器通讯失败

电解质样本传送单元上下运动错误电解质样本传送单元旋转运动错误电解质样本针液面探测器错误电解质样本分配器错误

电解质样本针内部清洗分配器错误电解质样本分配器压力探测错误电解质缓冲液分配器错误电解质缓冲液分配器错误

电解质样品混合池液面传感器错误电解质样品混合池液面传感器错误电解质样品混合池溢出电解质样品混合池溢出

电解质模拟放大器电源模块错误电解质模拟放大器电源模块错误电解质样本注射器灌注未完成

电解质定标液非法设定

电解质废液排放未完成?电解质数据处理器错误电解质数据处理器错误电解质数据处理器错误电解质搅拌马达错误电解质搅拌马达错误电解质内标液蠕动泵错误电解质内标液蠕动泵错误电解质吸样蠕动泵错误电解质吸样蠕动泵错误电解质单元控制错误电解质单元控制错误 电解质样本量少

电解质样品针清洗液少

电解质样本针清洗液已用完电解质样本针清洗液已用完电解质样本针探测到凝块样本针吸样失败电解质缓冲液少电解质内标液少电解质参比液少电解质清洗液少

电解质血清高值定标液少电解质血清低值定标液少电解质尿液高值定标液少电解质尿液低值定标液少电解质Na电极选择性检查液少电解质K电极选择性检查液少电解质CRS标准液(高值)少

电解质CRS标准液(中值)少电解质CRS标准液(低值)少

电解质CRS标准液(高值)少(尿液)电解质CRS标准液(中值)少(尿液)电解质CRS标准液(低值)少(尿液)电解质上盖未盖好电解质上盖未盖好电解质样品针撞针浓缩计算失败?浓缩计算失败?电解质顺序运行错误电解质顺序运行错误

电解质预测量中值定标液稳定性错误电解质预测量中值定标液稳定性错误电解质内标液稳定性错误(测量中)电解质内标液稳定性错误(测量中)电解质血清标准液(高值)稳定性错误电解质血清标准液(高值)稳定性错误电解质血清标准液(低值)稳定性错误电解质血清标准液(低值)稳定性错误电解质尿液标准液(高值)稳定性错误电解质尿液标准液(高值)稳定性错误电解质尿液标准液(低值)稳定性错误电解质尿液标准液(低值)稳定性错误钠低浓度值错误钠低浓度值错误钠低浓度值错误试剂瓶更换

试剂空白/定标无试剂瓶试剂空白/定标试剂少试剂仓正在使用

试剂空白/定标预稀释液少样品针撞针R1试剂针撞针R2试剂针撞针

样品针灌注未完成试剂瓶非法设置样本针定期清洗

试剂条形码错误(诊断检查时)去离子水少去离子水空去离子水空去离子水溢出

去离子水供应不足去离子水供应不足清洗原液空清洗原液空

清洗原液供应不足清洗原液溢出试剂针位置错误

清洗样品杯过程中出现光度测量错误

分析仪程序错误分析仪程序错误1

分析仪程序错误2分析仪程序错误3分析仪机械错误分析仪机械错误1分析仪机械错误2分析仪机械错误3分析仪修正信息分析仪修正信息分析仪修正信息分析仪修正信息

分析仪程序下载完成

初始化预热待机

运行开始最后样品架

测量转换到暂停状态测量转换到停止状态

暂停停止

系统停止W1清洗开始W2清洗开始光校准开始W1清洗结束W2清洗结束光校准结束光校准失败测试结束转向停止W1清洗失败W2清洗失败空白索引删除

空白反应数据删除空白质控索引删除

日期索引更新日期索引删除反应数据被删除质控索引删除

电解质定标开始

电解质电极选择性检查开始电解质CRS定标开始电解质清洗开始

电解质增强型清洗开始电解质定标完成

电解质电极选择性检查完成电解质CRS定标完成电解质清洗完成

电解质增强型清洗完成开机登录注销

登录失败

改密失败无试剂瓶

试剂条码阅读错误试剂条码阅读错误试剂条码未定义非法试剂类型

R2试剂瓶被发现放置在R1试剂仓内R1试剂瓶被发现放置在R2试剂仓内非法试剂瓶类型非法试剂瓶位置试剂过期

某试剂被发现有不同批号试剂在一起使用试剂类型更换试剂瓶类型更换试剂体积超过上限

光电校正数据错误比色杯平均值检查错误

光电校正光源灯检查错误孵育室温度高

孵育室温度低

试剂仓温度高试剂仓温度低危险测量值

HbA1c预处理检查范围错误HbA1c计算检查失败无颜色数据无空白数据

试剂空白数据错误定标因数高出范围定标因数低于范围定标吸光度高出范围定标吸光度低于范围

定标错误

多点定标吸光度斜率检查错误

1/2点定标校正因子错误质控数据超出范围质控数据低于范围

质控数据多规则检查错误质控数据偏离检查错误电解质CRS定标失败HbA1c批号不匹配反应曲线检查错误?

速率法下降反应检查错误?线性检查错误

反应曲线连续调整错误无样品杯(管)样品无申请单样品管无条形码

此样品无测试项目申请

此样品申请号超出最大样品号样本计算错误

破损标签

样品条形码阅读错误

读条形码的样品测量完成读条形码的样品测量完成读条形码的样品测量完成样品架使用错误RB样本架设置错误不合格样品ID常规重测不可用

校准/质控申请目录一部分测试申请已取消存在一个波长没有按设定进行写入的危险

测试代码不匹配时检查相关参数改变测试代码时检查相关参数文件未找到文件写入错误未选择打印机

部分数据仍未输出打印机繁忙删除样本失败

因达最大样本号无法申请项目无试剂空白数据无校准数据

在线传输错误

在线传输格式错误在线传输非法文本代码在线传输非法文本块编号在线传输非法样品号在线传输非法样品架号在线传输非法性别文本在线传输非法年龄/日期在线传输分析方法不匹配在线传输样品号匹配不当

在线传输非法样品架号匹配不当在线传送与接收内容不配在线传输测量项目错误在线传输复查项目错误在线传输联接错误在线传输错误

在线传输格式错误在线传输设置错误

在线传输样本申请信息接收错误在线传输非法分析方法在线传输非法样本种类在线传输非法样本类型在线传输非法样本号在线传输非法样本架号在线传输非法性别信息在线传输非法年龄/日期在线传输非法病人信息在线传输非法样本ID

在线传输样本ID混合在线传输分析方法不匹配在线传输样本种类不匹配在线传输样本类型不匹配在线传输样本号不匹配在线传输样本架号不匹配在线传送与接收内容不配在线传输测量项目错误在线传输复查项目错误在线传输相同样本ID错误在线传输最大样本号错误在线传输样本存在错误在线传输等待传输

样本登记按照主机指示完成当前索引有未完成的样本

启动浏览程序失败perplink 传输错误项目ID未找到测试计算错误设置定标信息

样本空白超过最大设定值无试剂参数设置定标信息执行定标

设置定标品信息测量单位已改变

控制电脑与生化仪之间通讯错误

控制电脑与电解质模块之间通讯错误控制电脑与生化仪之间通讯错误不同版本文件无数据文件打印机错误报警号未发现数据管理编辑质控数据编辑

自动重测数据覆盖原始数据重新计算数据数据修正样本ID编辑数据更新错误样本ID重复

重新计算定标数据程序错误程序文件修正文件

关机后重新开机;联系工程师关机后重新开机;联系工程师

复位后重新开始测试;联系工程师关机后重新开机;联系工程师关机后重新开机;联系工程师

查看报警详细内容判断原因;联系工程师

关机后重新开机;联系工程师关机后重新开机;联系工程师请求厂家工程师指导请求厂家工程师指导请求厂家工程师指导

样品针在测量开始时下降到冲洗池小孔内无水流出,查看水桶插头插紧?样品针在测量开始时下降到冲洗池小孔内无水流出,查看水桶插头插紧?样品针堵?分配电磁阀上部水管脱落,堵孔探测传感器故障?

试剂针在测量开始时下降到冲洗池小孔内无水流出,查看水桶插头插紧?试剂针在测量开始时下降到冲洗池小孔内无水流出,查看水桶插头插紧?试剂针在测量开始时下降到冲洗池小孔内无水流出,查看水桶插头插紧?试剂针在测量开始时下降到冲洗池小孔内无水流出,查看水桶插头插紧?请求厂家工程师指导请求厂家工程师指导增加样本量

查看样本血清质量,重做测试

查看样品量;样品针堵塞?使用通针疏通添加样品针清洗液添加样品针清洗液添加样品针清洗液添加样品针W2清洗液添加样品针清预稀释液添加样品针清预稀释液添加样品针清预稀释液添加样品针清预稀释液添加样品针清预稀释液添加R1试剂添加R1试剂添加R1试剂添加R1试剂添加R1试剂

添加R1试剂针清洗液添加R1试剂针清洗液添加R1试剂针清洗液添加R1试剂针W2清洗液添加R2试剂添加R2试剂添加R2试剂添加R2试剂添加R2试剂

添加R2试剂针清洗液添加R2试剂针清洗液添加R2试剂针清洗液添加R2试剂针W2清洗液

补充清洗原液

DI(去离子)水桶下端出水接头未插好,DI水桶内水少,浮子插头未插好重新插拔稀释清洗液桶浮子插头,联系工程师重新插拔稀释清洗液桶浮子插头,联系工程师

检查冲洗站废液罐上盖是否拧紧,胶皮圈变形,真空泵膜片老化外部下水管道堵;冲洗站废液罐下水管道堵,排泄不畅,逐级查找外部下水管道堵;废液泵及前后管道堵,排泄不畅,逐级查找

外部下水管道堵;废液泵故障或前后管道堵,排泄不畅,逐级查找关机后重新开机;联系工程师关机后重新开机;联系工程师更换光源灯

检查比色杯是否溢出流入孵育室;光源灯老化盖好R1试剂仓盖盖好R1试剂仓盖盖好R2试剂仓盖盖好R2试剂仓盖

复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师

复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师

样品混合池内液面升高,蠕动泵管老化,废液池堵塞样品混合池内液面升高,蠕动泵管老化,废液池堵塞样品混合池内液面升高,蠕动泵管老化,废液池堵塞样品混合池内液面升高,蠕动泵管老化,废液池堵塞复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师电解质血清或尿高、低定标液未成对设定

复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师关机后重新开机;联系工程师关机后重新开机;联系工程师

补充电解质缓冲液补充电解质内标液补充电解质参比液补充电解质清洗液

补充电解质血清高值定标液补充电解质血清低值定标液补充电解质尿液高值定标液补充电解质尿液低值定标液补充Na电极选择性检查液补充K电极选择性检查液

复位后重新开始测试;联系工程师复位后重新开始测试;联系工程师

提示:分析仪正在自动更换该试剂已设定的其它瓶安放试剂空白试剂瓶补充该项目试剂

提示:试剂仓内试剂盘正在旋转,请勿打开试剂仓盖。补充试剂空白/定标预稀释液

调整样品针位置(进入Anl Diag.→Diag Start→Sample Transfer→up/down按下急诊台绿键)发生在试剂仓时,可能是试剂瓶不正,发生在其它位置参见样品针撞针调整方法(3240)。

发生在试剂仓时,可能是试剂瓶不正或放反;发生在其它位置参见样品针撞针调整方法(3240)。样品针灌注时间很长,提前退出就会发生此报警

诊断功能检查样品条形码错误

检查水处理机水是否工作;进水管道是否有空气,拔出4号管放气检查水处理机水是否工作;进水管道是否有空气,拔出4号管放气检查水处理机水是否工作;进水管道是否有空气,拔出4号管放气4号进水管后电磁阀被杂物卡住,打开电磁阀取出杂物

未料到的可编程序事件发生;关机后重新开机;联系工程师未料到的可编程序事件发生;关机后重新开机;联系工程师

未料到的可编程序事件发生;关机后重新开机;联系工程师未料到的可编程序事件发生;关机后重新开机;联系工程师未料到的可编程序事件发生;关机后重新开机;联系工程师未料到的可编程序事件发生;关机后重新开机;联系工程师未料到的可编程序事件发生;关机后重新开机;联系工程师未料到的可编程序事件发生;关机后重新开机;联系工程师程序修正信息提示,不影响分析仪正常运行程序修正信息提示,不影响分析仪正常运行程序修正信息提示,不影响分析仪正常运行程序修正信息提示,不影响分析仪正常运行程序进程提示

新建日期索引提示删除日期索引提示

试剂条码阅读错误提示试剂条码阅读错误提示

试剂条码未定义提示,检查试剂条形码,更换。检查试剂条类型,更换。正确放置试剂瓶正确放置试剂瓶

试剂瓶类型不正确,冲洗确认

试剂瓶放置不正确,重新确认更换未超有效期试剂

每一次测试应使用同一批号试剂试剂瓶类型更换的提示光电校正数据错误的提示

比色杯平均值检查错误的提示光电校正光源灯检查错误的提示

恒温液缺少,适量补充;仍有报警联系工程师

补充恒温液,按下恒温液加热器中间保护开关的复位按钮;仍有报警联系工程师清洗分析仪空气过滤网;联系工程师

正常关机后再按下分析仪桔黄色按钮全部关机,重新开机;仍有报警联系工程师测量结果超出设定的危险值,查找原因

HbA1c预处理检查范围错误提示HbA1c计算检查失败提示

TBIL,DBIL样品空白试验中由于某种原因缺少Color Test数据,检查样品测试过程中是否有堵孔无样品空白数据提示

试剂空白数据错误提示定标因数高出范围提示定标因数低于范围提示定标吸光度高出范围提示定标吸光度低于范围提示定标错误提示

多点定标吸光度斜率检查错误提示

质控数据超出范围提示质控数据低于范围提示

质控数据多规则检查错误提示电解质CRS定标失败提示HbA1c批号不匹配提示

无样品杯(管)提示

已放置样品管但该样品无申请单,应输入试验申请单系统设置为样品条形码扫描但样品管无条形码此样品有申请号但无测试项目申请此样品申请号超出最大样品号提示

1.条形码读出2个样品管为同一内容。2.该样品是申请的样品架号但放置在了急诊台。1.样品管的条形码不能被正确阅读。2.该样品是申请的样品架号但放置在了急诊台。读条形码的样品测量完成提示读条形码的样品测量完成提示读条形码的样品测量完成提示

检查样品架颜色确定使用正确的样品架

在线传输错误提示,请查看发送或接受的申请单病人信息错误

在线通讯中的标本响应信息,1个必须的标本信在参数设定中未选\"YES\".在线传输非法文本代码提示,请查看( )内详细内容在线传输非法文本块编号提示在线传输非法样品号提示在线传输非法样品架号提示在线传输非法性别文本提示在线传输非法年龄/日期提示在线传输样品号匹配不当提示

在线传输非法样品架号匹配不当提示在线传送与接收内容不配提示在线传输测量项目错误提示在线传输复查项目错误提示

绿键)

方法(3240)。

堵孔

因篇幅问题不能全部显示,请点此查看更多更全内容